Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufpe.br/handle/123456789/67740
Comparte esta pagina
Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.advisor | VAJGEL, Bruna de Carvalho Farias | - |
| dc.contributor.author | SILVA, Myllena Rodrigues e | - |
| dc.date.accessioned | 2026-01-20T20:27:53Z | - |
| dc.date.available | 2026-01-20T20:27:53Z | - |
| dc.date.issued | 2025-12-04 | - |
| dc.date.submitted | 2026-01-17 | - |
| dc.identifier.citation | SILVA, Myllena Rodrigues e. Avaliação in vitro da viscosidade de resinas compostas regulares submetidas ao pré-aquecimento. 2026. Trabalho de Conclusão de Curso (Bacharelado em Odontologia) - Universidade Federal de Pernambuco, Recife, 2025. | pt_BR |
| dc.identifier.uri | https://repositorio.ufpe.br/handle/123456789/67740 | - |
| dc.description.abstract | O objetivo deste estudo foi avaliar a influência do pré-aquecimento na viscosidade complexa (η*) e nos módulos viscoelásticos de resinas compostas regulares utilizadas como agentes cimentantes. Tratou-se de um estudo in vitro composto por 30 amostras (N = 10 por grupo), no qual foram analisados três grupos: RV (RelyX Veneer, 25 °C), HC (Herculite Classic, 69 °C) e Z100 (Filtek Z100, 69 °C). As análises foram conduzidas em um reômetro de placas paralelas HAAKE MARS III (Thermo Fisher Scientific, Waltham, EUA), utilizando varredura oscilatória para obtenção de G’ (módulo de armazenamento), G’’ (módulo de perda) e η* (viscosidade complexa) em frequências de 0,01 a 100 rad/s. Os resultados mostraram que o grupo RV apresentou os maiores valores de G’, G’’ e η*, evidenciando maior rigidez estrutural e menor susceptibilidade ao escoamento. O pré-aquecimento reduziu de forma acentuada os módulos viscoelásticos das resinas HC e Z100, tornando-as mais fluidas e com comportamento típico de materiais pseudoplásticos, caracterizado pela redução progressiva da viscosidade com o aumento da frequência. Entre as resinas aquecidas, a HC apresentou valores intermediários, enquanto a Z100 mostrou os menores valores de G’, G’’ e η*, indicando maior sensibilidade térmica. Conclui-se que o pré-aquecimento promove redução significativa da viscosidade e melhora da fluidez das resinas compostas regulares, favorecendo seu potencial uso como agentes cimentantes. Com isso, o pré-aquecimento se mostrou como uma estratégia promissora, porém depende de controle rigoroso e maior padronização para ser aplicado com segurança na cimentação odontológica. | pt_BR |
| dc.format.extent | 31 p. | pt_BR |
| dc.language.iso | por | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | pt_BR |
| dc.subject | Resinas compostas | pt_BR |
| dc.subject | Viscosidade | pt_BR |
| dc.subject | Reologia | pt_BR |
| dc.subject | Cimentação | pt_BR |
| dc.title | Avaliação in vitro da viscosidade de resinas compostas regulares submetidas ao pré-aquecimento | pt_BR |
| dc.type | bachelorThesis | pt_BR |
| dc.contributor.advisor-co | PAULO, Jonathas José de | - |
| dc.contributor.authorLattes | http://lattes.cnpq.br/6857271041072017 | pt_BR |
| dc.degree.level | Graduacao | pt_BR |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/0479416826444281 | pt_BR |
| dc.description.abstractx | The aim of this study was to evaluate the influence of preheating on the complex viscosity (η*) and viscoelastic moduli of regular composite resins used as cementing agents. This was an in vitro study composed of 30 samples (N = 10 per group), in which three groups were analyzed: RV (RelyX Veneer, 25 °C), HC (Herculite Classic, 69 °C) and Z100 (Filtek Z100, 69 °C). The analyses were conducted on a HAAKE MARS III parallel plate rheometer (Thermo Fisher Scientific, Waltham, USA), using oscillatory sweep to obtain G’ (storage modulus), G’’ (loss modulus) and η* (complex viscosity) at frequencies from 0.01 to 100 rad/s. The results showed that the RV group presented the highest values of G’, G’’, and η*, evidencing greater structural rigidity and lower susceptibility to flow. Preheating significantly reduced the viscoelastic moduli of the HC and Z100 resins, making them more fluid and exhibiting typical pseudoplastic material behavior, characterized by a progressive reduction in viscosity with increasing frequency. Among the heated resins, HC showed intermediate values, while Z100 showed the lowest values of G’, G’’, and η*, indicating greater thermal sensitivity. It is concluded that preheating significantly reduces the viscosity and improves the fluidity of regular composite resins, favoring their potential use as cementing agents. Therefore, preheating proved to be a promising strategy, but it depends on rigorous control and greater standardization to be safely applied in dental cementation. | pt_BR |
| dc.subject.cnpq | Áreas::Ciências da Saúde::Odontologia | pt_BR |
| dc.degree.departament | ::(CCS-DPCB) - Departamento de Prótese e Cirurgia Buco Facial | pt_BR |
| dc.degree.graduation | ::CCS-Curso de Odontologia | pt_BR |
| dc.degree.grantor | Universidade Federal de Pernambuco | pt_BR |
| dc.degree.local | Recife | pt_BR |
| dc.contributor.advisor-coLattes | http://lattes.cnpq.br/0244763487625839 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0003-2859-3533 | pt_BR |
| Aparece en las colecciones: | (TCC) - Odontologia | |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| TCC MYLLENA RODRIGUES E SILVA.pdf | 2.65 MB | Adobe PDF | ![]() Visualizar/Abrir |
Este ítem está protegido por copyright original |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons

