dc.contributor.advisor | OLIVEIRA, Tiago Anselmo de Carvalho Pires | - |
dc.contributor.author | SANTOS, Marina Machado Leal dos | - |
dc.date.accessioned | 2022-12-20T19:23:27Z | - |
dc.date.available | 2022-12-20T19:23:27Z | - |
dc.date.issued | 2015-12-15 | - |
dc.date.submitted | 2022-12-15 | - |
dc.identifier.citation | SANTOS, Marina Machado Leal dos. Considerações iniciais sobre o comportamento de lajes mistas ―steel deck‖ em situação de incêndio. 2015. 52 f. TCC (Graduação) - Curso de Engenharia Civil, Centro de Tecnologia e Geociências, Universidade Federal de Pernambuco, Recife, 2016. | pt_BR |
dc.identifier.uri | https://repositorio.ufpe.br/handle/123456789/48302 | - |
dc.description.abstract | Atualmente, lajes mistas em aço e concreto do tipo Steel Deck são largamente utilizadas na indústria da construção civil brasileira. Esta opção deve-se a uma série de vantagens deste elemento, cita-se, por exemplo, a simplicidade de construção e dimensionamento das mesmas, o fato do sistema construtivo já oferecer de uma só vez a forma, a armadura longitudinal e a dispensa de acabamento. Estes fatores contribuem para que a laje Steel Deck seja uma alternativa bastante interessante do ponto de vista construtivo e econômico. No entanto, o comportamento deste tipo de laje em situação de incêndio ainda é pouco conhecido na literatura internacional. Sabe-se que, nesta situação, as propriedades mecânicas do aço e do concreto serão reduzidas com o aumento de temperatura, podendo comprometer o desempenho estrutural. Somado a isto, o fato da chapa metálica ser de pequena espessura e localizada na parte inferior da laje e, por muitas vezes sem proteção ao fogo, podem agravar ainda mais as consequências do incêndio. A NBR 15575:2013, norma de desempenho para edificações habitacionais, traz consigo as exigências em relação a segurança estrutural, segurança contra o fogo e segurança no uso e na operação. Em se tratando de segurança contra o fogo esta norma prevê que os métodos de avalição contra incêndio devem atender à NBR 14323 para estruturas de aço, à NBR 15200 para estruturas de concreto e ao Eurocode correspondente para as demais estruturas. O dimensionamento deste tipo de elemento nesta situação é previsto pela NBR 14323:2013 – Anexo C. A norma apresenta um método tabular para se determinar o Tempo de Resistência Requerido ao Fogo (TRRF) em função da altura equivalente da Laje. Um modelo tridimensional em elementos finitos desenvolvido no software ABAQUS. Como estudo de caso será analisada uma laje de concreto de fck20MPa com 1m de largura, 2,8m de comprimento e 14cm de altura conjuntamente à chapa de fy280MPa de mesmas altura e largura, com espessura de 0,95mm. Seus resultados serão comparados com o método tabular prescrito pela NBR14323:2013 e com outros resultados divulgados na revisão de literatura. A chapa de aço da laje em estudo apresentou temperaturas muito elevadas para o tempo de resistência ao fogo recomendado pela norma 970°C em 90 min e por seu fabricante 677°C em 30 min. O tempo crítico determinado pela simulação foi de 20min, onde a chape de aço atingiu 500°C. Espera-se que estes resultados sirvam para desencadear uma discussão a sobre a resistência ao fogo das lajes Steel Deck utilizadas em nossa região. | pt_BR |
dc.format.extent | 52p. | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | openAccess | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | * |
dc.subject | Engenharia Civil | pt_BR |
dc.subject | Lajes | pt_BR |
dc.subject | Aço | pt_BR |
dc.subject | Concreto | pt_BR |
dc.subject | Steel-Deck | pt_BR |
dc.subject | Resistência ao fogo | pt_BR |
dc.title | Considerações iniciais sobre o comportamento de lajes mistas ―steel deck‖ em situação de incêndio | pt_BR |
dc.type | bachelorThesis | pt_BR |
dc.degree.level | Graduacao | pt_BR |
dc.contributor.advisorLattes | http://lattes.cnpq.br/7169964295024046 | pt_BR |
dc.description.abstractx | On our days, Steel Deck slabs are largely utilized on the Brazilian’s civil construction industry. This option is due to many advantages that this element can offer, for example, their construction and scaling simplicity the fact that the construction system offers at once the formwork, the longitudinal armor and the not needing of finishing details which can many time be a simple painter. Those facts contribute to make the Steel Deck system an interesting alternative in the constructive and economical points of view. On the other hand, the behavior of this kind of slab on fire situation steel is much unknown by the international literature. On fire situation, the steel’s and concrete’s mechanical properties are reduced by a temperature enhancement. Such reduction can affect the structural performance of this element. Adding to this fact, the short dimension of the transversal section, the fact that the metallic plate is thick and located on the inferior surface of the slab, and for many times, which no fire protection, can aggravate the fire situation consequences. So it’s necessary to the civil engineer the knowledge to scale those slabs on fire situation. The NBR 15575: 2013 performance standard for residential buildings, brings the requirements regarding structural safety, fire safety and security in the use and operation. When it comes to fire safety this standard provides that the methods of evaluation on fire situation must be according to the NBR 14323 for steel structures, the NBR 15200 for concrete structures and the corresponding Eurocode to other structures. The Scaling of this category of slabs is previewed by NBR 14323:2013 – C Annex. The Brazilian standard presents a table method to determinate the Time Required for Fire Resistance (TRRF) accord to the slab equivalent height. The standard also allows the utilization of advanced methods for the element’s fire resistance determination, but, those models requires a greater knowledge from the professional for its utilization. A tridimensional model in finites elements developed on ABAQUS. As a practical case a concrete slab witch fck 20Mpa and 1m width, 2,80m length, and 14cm height concomitant to the steel witch fy280Mpa, 0,95mmheight and the same width and length as the concrete part. Their results will be compared with the tabular method prescribed by NBR 14323:2013 and others results other results present on the literature revision. The Steel Deck developed high temperatures for the time required for fire resistance recommended by Brazilian standard 970°C in 90min and by its manufacturer 677?C in 30 min. It is expected that the results of this study serves to initiate a start a discussion about the fire resistance of the Steel Deck slabs utilized in our region. | pt_BR |
dc.subject.cnpq | Engenharias::Engenharia Civil | pt_BR |
dc.degree.departament | (CTG-DECV) - Departamento de Engenharia Civil | pt_BR |
dc.degree.graduation | CTG-Curso de Engenharia Civil | pt_BR |
dc.degree.grantor | Universidade Federal de Pernambuco | pt_BR |
dc.degree.local | Recife | pt_BR |
Aparece nas coleções: | (TCC) - Engenharia Civil e Ambiental |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
MARINA MACHADO LEAL DOS SANTOS-CONSIDERAÇÕES INICIAIS SOBRE O COMPORTAMENTO DE LAJES MISTAS “STEEL DECK” EM SITUAÇÃO DE INCÊNDIO.pdf | 2,05 MB | Adobe PDF | ![]() Visualizar/Abrir |
Este arquivo é protegido por direitos autorais |
Este item está licenciada sob uma Licença Creative Commons