Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufpe.br/handle/123456789/48199
Comparte esta pagina
Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.advisor | AZEVEDO, José Roberto Gonçalves de | - |
| dc.contributor.author | BRIANO, Antonio José Moura | - |
| dc.date.accessioned | 2022-12-14T16:10:20Z | - |
| dc.date.available | 2022-12-14T16:10:20Z | - |
| dc.date.issued | 2020-04-08 | - |
| dc.date.submitted | 2022-12-13 | - |
| dc.identifier.citation | BRIANO, Antonio José Moura. Pré-diagnóstico da eficiência hidráulica-energética de sistemas elevatórios de água bruta na região metropolitana do Recife. 2020. 75 f. TCC (Graduação) - Curso de Engenharia Civil, Centro de Tecnologia e Geociências, Universidade Federal de Pernambuco, Recife, 2020. | pt_BR |
| dc.identifier.uri | https://repositorio.ufpe.br/handle/123456789/48199 | - |
| dc.description.abstract | As despesas com energia elétrica no serviço de saneamento básico tendem a aumentar ano após ano. Em 2017 foram consumidos no Brasil, somente com saneamento ambiental, 12,6 TWh de energia, sendo 11,3 TWh com abastecimento de água e 1,3 TWh com esgotamento sanitário. Tendo em vista as perdas que o sistema de saneamento ambiental sofre e a escassez dos recursos financeiros, propôs-se a elaboração do “Pré-diagnóstico das eficiências eletromecânicas e hidroenergéticas de sistemas elevatórios de água” para o monitoramento de sistemas elevatórios. A metodologia, baseada no cálculo do Consumo Energético Normalizado – CEN e estimativa do payback, visa economizar recursos à medida que direciona esforços para os sistemas mais críticos. O trabalho foi desenvolvido em planilha de cálculo e o estudo de caso abrange as elevatórias de Duas Unas, Vertentes Doce e mais cinco estações do sistema de elevação da Barragem de Botafogo, totalizando oito elevatórias de água bruta da Companhia Pernambucana de Saneamento – COMPESA. Foi estimado o potencial de economia mensal total para as oito elevatórias no valor de 259 mil reais. Significa dizer que, caso as intervenções sugeridas sejam bem sucedidas, poder-se-ia economizar cerca de 3 milhões e cem mil reais por ano. Entretanto, deve-se destacar que a metodologia apenas leva em consideração fatores hidromecânicos, não avaliando méritos operacionais que também influenciam na eficiência energética dos equipamentos, como por exemplo, o transiente hidráulico e a disponibilidade hídrica da região. | pt_BR |
| dc.format.extent | 75p. | pt_BR |
| dc.language.iso | por | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | * |
| dc.subject | Engenharia civil | pt_BR |
| dc.subject | Saneamento ambiental | pt_BR |
| dc.subject | Consumo energético normalizado | pt_BR |
| dc.subject | Potencial de economia | pt_BR |
| dc.title | Pré-diagnóstico da eficiência hidráulica-energética de sistemas elevatórios de água bruta na região metropolitana do Recife | pt_BR |
| dc.type | bachelorThesis | pt_BR |
| dc.contributor.advisor-co | MAGALHÃES, Cláudio Henrique Milfont de | - |
| dc.degree.level | Graduacao | pt_BR |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/8967681489869245 | pt_BR |
| dc.description.abstractx | Electricity expenses in the basic sanitation service tend to increase year after year. In 2017, 12.6 TWh of energy was consumed in Brazil, only with environmental sanitation, of which 11.3 TWh with water supply and 1.3 TWh with sanitary sewerage. In view of the losses that the environmental sanitation system suffers and the scarcity of financial resources, it was proposed to elaborate the “Pre-Diagnosis of Electromechanical and Hydroenergetic Efficiencies of Water Pumping Systems” for the monitoring of pumping systems. The methodology, based on the calculation of the Normalized Energy Consumption - CEN and the payback estimate, aims to save resources as it directs efforts to the most critical systems. The work was developed in spreadsheet and the case study covers some of the raw water pumping systems of the Pernambuco Sanitation Company - COMPESA. The total monthly savings potential for the eight elevations was estimated at R $ 259 thousand. It means that if the suggested interventions are successful, it could save about 3 million and one hundred thousand reais per year. However, it should be noted that the methodology only considers hydromechanical factors, not evaluating operational merits that also influence the energy efficiency of the equipment, such as, for example, the hydraulic transient and water availability in the region. | pt_BR |
| dc.degree.departament | (CTG-DECV) - Departamento de Engenharia Civil | pt_BR |
| dc.degree.graduation | CTG-Curso de Engenharia Civil | pt_BR |
| dc.degree.grantor | Universidade Federal de Pernambuco | pt_BR |
| dc.degree.local | Recife | pt_BR |
| dc.contributor.advisor-coLattes | http://lattes.cnpq.br/1987719441445376 | pt_BR |
| Aparece en las colecciones: | (TCC) - Engenharia Civil e Ambiental | |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| TCC - ANTONIO_BRIANO.pdf | 2.22 MB | Adobe PDF | ![]() Visualizar/Abrir |
Este ítem está protegido por copyright original |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons