Skip navigation
Please use this identifier to cite or link to this item: https://repositorio.ufpe.br/handle/123456789/48032

Share on

Full metadata record
DC FieldValueLanguage
dc.contributor.advisorFITTIPALDI, Andrea Diniz-
dc.contributor.authorFIGUEIRÔA NETO, Antão Gonçalves-
dc.date.accessioned2022-11-30T18:05:38Z-
dc.date.available2022-11-30T18:05:38Z-
dc.date.issued2020-04-27-
dc.date.submitted2022-11-29-
dc.identifier.citationFIGUEIRÔA NETO, Antão Gonçalves. Patologias nos sistemas prediais hidráulicos de Água Fria. 2020. 58 f. TCC (Graduação) - Curso de Engenharia Civil, Centro de Tecnologia e Geociências, Universidade Federal de Pernambuco, Recife, 2020.pt_BR
dc.identifier.urihttps://repositorio.ufpe.br/handle/123456789/48032-
dc.description.abstractEsse trabalho investigou os problemas/falhas mais incidentes nas instalações hidráulicas de água fria das edificações do Recife, suas causas e as consequências para a edificação. Para desenvolver essa investigação, inicialmente foi feito o estudo de uma bibliografia associada ao tema para se adquirir conhecimentos sobre os sistemas prediais hidráulicos de água fria e as possíveis patologias que neles podem ocorrer. Em seguida, para se investigar os problemas e falhas mais incidentes nas instalações hidráulicas prediais das edificações de Recife, as suas causas e as consequências geradas na edificação, foram realizadas entrevistas com oito profissionais da área. Os resultados das entrevistas realizadas demonstraram que os problemas mais recorrentes são o mau funcionamento dos vasos sanitários e pontos de utilização e os problemas de sobrepressão interna nas tubulações, que, por muitas vezes, vêm a gerar o golpe de aríete, e o rompimento e/ou aberturas nas tubulações ou conexões. Quanto às causas, foram destacados os erros de dimensionamento em projeto, a má instalação dos dispositivos, com ênfase nos erros de colagem de tubulações e conexões e à má utilização do sistema pelos usuários e/ou falta de manutenção por eles. Finalmente as consequências ressaltadas foram o desconforto ao usuário, os prejuízos financeiros e os danos à estrutura, principalmente na forma de rachaduras nas paredes. As ações propostas para solucionar ou, pelo menos, minimizar as causas foram as seguintes: a concepção do projeto de forma séria e efetivamente obedecendo aos requisitos estabelecidos na NBR 5626, o atendimento às especificações de projeto quanto à realização dos processos construtivos e uma contínua realização de treinamentos com os responsáveis pela atividade de instalação dos dispositivos e a conscientização dos usuários, a ser promovida pela construtora, sobre a correta utilização do sistema e o cumprimento das manutenções preventivas previstas no Manual de Uso e Ocupação da Edificação.pt_BR
dc.format.extent58p.pt_BR
dc.language.isoporpt_BR
dc.rightsopenAccesspt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/*
dc.subjectEngenharia civilpt_BR
dc.subjectPatologias hidrossanitáriaspt_BR
dc.subjectSistema hidráulico predialpt_BR
dc.subjectManutenções preventivaspt_BR
dc.subjectPrevenção de problemas hidráulicospt_BR
dc.titlePatologias nos sistemas prediais hidráulicos de Água Friapt_BR
dc.typebachelorThesispt_BR
dc.degree.levelGraduacaopt_BR
dc.contributor.advisorLatteshttp://lattes.cnpq.br/7611128072751756pt_BR
dc.description.abstractxThis work investigated the most frequent problems / failures in the cold water hydraulic installations of the buildings in Recife, their causes and their consequences for the buildings. To develop this investigation, initially a study of the bibliography related to the theme was made to acquire knowledge about the hydraulic building systems of cold water and the possible pathologies that may occur in them. Then, to investigate the most frequent problems and failures in the building's hydraulic installations in buildings in Recife, their causes and the consequences generated in the building, interviews were carried out with eight professionals in the area. The results of the interviews carried out demonstrated that the most recurrent problems are the malfunctioning of the toilets and points of use and the problems of internal pressure in the pipes, which, many times, generate the water hammer, and the rupture and / or openings in the pipes or connections. As for the causes, the design sizing errors, the poor installation of the devices, with emphasis on the errors of gluing pipes and connections and the misuse of the system by the users and / or lack of maintenance by them, were highlighted. Finally, the highlighted consequences were user ́s discomfort, financial losses and damage to the structure, mainly in the form of cracks in the walls. The proposed actions to solve or, at least, minimize the causes were the following: the design of the project in a serious way and effectively obeying the requirements established in NBR 5626, the fulfillment of the project specifications regarding the realization of the construction processes and a continuous realization training with those responsible for the installation of the devices and the awareness of users, to be promoted by the construction company, on the correct use of the system and compliance with the preventive maintenance provided for in the Building Use and Occupation Manual.pt_BR
dc.subject.cnpqÁreas::Engenharias::Engenharia Civilpt_BR
dc.degree.departament::(CTG-DECV) - Departamento de Engenharia Civil pt_BR
dc.degree.graduation::CTG-Curso de Engenharia Civilpt_BR
dc.degree.grantorUniversidade Federal de Pernambucopt_BR
dc.degree.localRecifept_BR
Appears in Collections:(TCC) - Engenharia Civil e Ambiental

Files in This Item:
File Description SizeFormat 
TCC FINAL PRONTO Antãobiblioteca CONCLUIDO TOTALMENTE.pdf1.87 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons