Please use this identifier to cite or link to this item:
https://repositorio.ufpe.br/handle/123456789/67427
Share on
Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.advisor | FIGUEIREDO, Viviane Maria Gonçalves de | - |
| dc.contributor.author | SILVA, Sandro Matheus Albuquerque da | - |
| dc.date.accessioned | 2026-01-06T18:14:07Z | - |
| dc.date.available | 2026-01-06T18:14:07Z | - |
| dc.date.issued | 2025-12-04 | - |
| dc.date.submitted | 2025-12-30 | - |
| dc.identifier.citation | SILVA, Sandro Matheus Albuquerque da. EFEITO DO ENVELHECIMENTO SOBRE AS PROPRIEDADES SUPERFICIAIS E MECÂNICAS ENTRE A RESINA CONVENCIONAL E RESINA IMPRESSA 3D PARA BASE DE PRÓTESE. 2025. Trabalho de Conclusão de Curso (Bacharelado em Odontologia) - Universidade Federal de Pernambuco, Recife, 2025. | pt_BR |
| dc.identifier.uri | https://repositorio.ufpe.br/handle/123456789/67427 | - |
| dc.description.abstract | Avaliar, por meio de um estudo in vitro, o efeito do envelhecimento sobre as propriedades superficiais e mecânicas de uma resina convencional e de uma resina impressa em 3D destinadas à base de prótese. Foram confeccionados espécimes de 10 × 10 × 2 mm, 10 × 2 mm e 65 × 20 × 3 mm utilizando resina termopolimerizável e resina impressa em 3D. Quatro grupos experimentais (N = 10) foram definidos: resina convencional antes (C) e após envelhecimento (CT), e resina impressa 3D antes (3D) e após envelhecimento (3DT). As propriedades superficiais foram avaliadas por Microscopia Eletrônica de Varredura, Perfilometria de Contato, Microscopia de Força Atômica e Rugosidade (Ra). As propriedades mecânicas foram investigadas por testes de Dureza, Resistência e Módulo de Flexão. Não foram observadas alterações superficiais relevantes antes e após o envelhecimento para ambos os materiais. A rugosidade (Ra) apresentou diferença significativa para o fator resina (p = 0,018). Na dureza, houve significância para resina (p = 0,000), envelhecimento (p = 0,038) e interação entre fatores (p = 0,000). Para resistência à flexão, os fatores resina (p = 0,009) e envelhecimento (p = 0,007) foram significativos. No módulo de flexão, apenas o fator resina apresentou significância estatística (p = 0,000). O processamento influencia as propriedades superficiais e mecânicas das resinas para base de prótese. O envelhecimento térmico promove alterações significativas sobre as resinas para base de prótese em relação à dureza e à resistência à flexão. | pt_BR |
| dc.format.extent | 45 p. | pt_BR |
| dc.language.iso | por | pt_BR |
| dc.rights | embargoedAccess | pt_BR |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | pt_BR |
| dc.subject | Bases de Dentadura | pt_BR |
| dc.subject | Impressão Tridimensional | pt_BR |
| dc.subject | Rugosidade de Superfície | pt_BR |
| dc.subject | Dureza | pt_BR |
| dc.subject | Resistência à Flexão | pt_BR |
| dc.subject | Envelhecimento | pt_BR |
| dc.title | EFEITO DO ENVELHECIMENTO SOBRE AS PROPRIEDADES SUPERFICIAIS E MECÂNICAS ENTRE A RESINA CONVENCIONAL E RESINA IMPRESSA 3D PARA BASE DE PRÓTESE | pt_BR |
| dc.type | bachelorThesis | pt_BR |
| dc.contributor.authorLattes | http://lattes.cnpq.br/0052933178278618 | pt_BR |
| dc.degree.level | Graduacao | pt_BR |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/0765787060233486 | pt_BR |
| dc.description.abstractx | To evaluate, through an in vitro study, the effect of aging on the surface and mechanical properties of a conventional resin and a 3D-printed resin used for denture bases. Specimens measuring 10 × 10 × 2 mm, 10 × 2 mm, and 65 × 20 × 3 mm were fabricated using a heat polymerized resin and a 3D-printed resin. Four experimental groups (N = 10) were established: conventional resin before (C) and after aging (CT), and 3D-printed resin before (3D) and after aging (3DT). Surface properties were assessed using Scanning Electron Microscopy, Contact Profilometry, Atomic Force Microscopy, and roughness (Ra) measurements. Mechanical properties were evaluated through hardness, flexural strength, and flexural modulus tests. No relevant surface alterations were observed before and after aging for either material. Roughness (Ra) showed a significant difference for the resin factor (p = 0.018). For hardness, significant differences were found for the resin (p = 0.000), aging (p = 0.038), and the interaction between factors (p = 0.000). Regarding flexural strength, both the resin factor (p = 0.009) and aging (p = 0.007) were statistically significant. For the flexural modulus, only the resin factor showed significance (p = 0.000). The processing method influences the surface and mechanical properties of denture base resins. Thermal aging causes significant changes in denture base resins with respect to hardness and flexural strength. | pt_BR |
| dc.subject.cnpq | Áreas::Ciências da Saúde::Odontologia | pt_BR |
| dc.degree.departament | ::(CCS-DPCB) - Departamento de Prótese e Cirurgia Buco Facial | pt_BR |
| dc.degree.graduation | ::CCS-Curso de Odontologia | pt_BR |
| dc.degree.grantor | Universidade Federal de Pernambuco | pt_BR |
| dc.degree.local | Recife | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-0464-6461 | pt_BR |
| Appears in Collections: | (TCC) - Odontologia | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| TCC - SANDRO MATHEUS ALBUQUERQUE DA SILVA.pdf Embargoed Item Until 2026-12-31 | 2.54 MB | Adobe PDF | View/Open Item embargoed |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
