Please use this identifier to cite or link to this item:
https://repositorio.ufpe.br/handle/123456789/48325
Share on
Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.advisor | MAGNUS, Bruna Scandolara | - |
| dc.contributor.author | SILVA, Wallaces Paulo da | - |
| dc.date.accessioned | 2022-12-21T11:48:15Z | - |
| dc.date.available | 2022-12-21T11:48:15Z | - |
| dc.date.issued | 2022-11-08 | - |
| dc.date.submitted | 2022-12-16 | - |
| dc.identifier.citation | SILVA, Wallaces Paulo da. Tratamento de esgoto doméstico com lodo granular aeróbio em reatores em bateladas sequenciais: pré-dimensionamento e critérios de projeto. 2022. 83 f. TCC (Graduação) - Curso de Engenharia Civil, Centro de Tecnologia e Geociências,Universidade Federal de Pernambuco, Recife, 2022. | pt_BR |
| dc.identifier.uri | https://repositorio.ufpe.br/handle/123456789/48325 | - |
| dc.description.abstract | O lodo granular aeróbio (LGA) é uma tecnologia promissora no tratamento biológico de efluentes domésticos, devido às altas eficiências de remoção simultânea de matéria orgânica e nutrientes em um único reator. Por se tratar de um sistema recém desenvolvido, este estudo teve como objetivo apresentar uma metodologia simplificada de dimensionamento dos principais componentes de uma estação de tratamento de esgoto (ETE) com LGA em escala real. Para atender à demanda futura da ETE Mangueira (vazão média de 96,35 L/s até 2047), são necessários dois reatores em bateladas sequenciais (RBS) de volume constante com 1514 m³, diâmetro de 20 metros em uma área de aproximadamente 0,65 hectares. O ciclo dos reatores teria duração total de 4 horas (fase de alimentação e descarte simultâneos definida em 45 minutos, reação aeróbia com tempo de 2 horas e 45 minutos e etapa de descanso com 30 minutos) e relação alimento/microrganismo de 0,4 kgDQO/kg.SST.dia. Verificou-se que é possível implementar sobre o ponto de vista técnico e ambiental uma ETE com LGA, especialmente quando se busca boa eficiência no tratamento, em um local com pouca área disponível. Constatou-se que para suprir as necessidades de tratamento futuras da ETE Mangueira com aplicação do LGA, é preciso uma área 52% menor que o atual tratamento com UASB e lagoas de polimento. | pt_BR |
| dc.format.extent | 83 p. | pt_BR |
| dc.language.iso | por | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | * |
| dc.subject | Saneamento básico | pt_BR |
| dc.subject | tratamento biológico de efluentes | pt_BR |
| dc.subject | viabilidade técnica e ambiental | pt_BR |
| dc.title | Tratamento de esgoto doméstico com lodo granular aeróbio em reatores em bateladas sequenciais: pré-dimensionamento e critérios de projeto | pt_BR |
| dc.type | bachelorThesis | pt_BR |
| dc.contributor.advisor-co | SALES, Marcos Adriano Marques Pessôa | - |
| dc.contributor.authorLattes | http://lattes.cnpq.br/6279485356614604 | pt_BR |
| dc.degree.level | Graduacao | pt_BR |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/7126445594531053 | pt_BR |
| dc.description.abstractx | The aerobic granular sludge (AGS) is a promising technology in the biological treatment of domestic wastewater, due to the high efficiencies of simultaneous removal of organic matter and nutrients in a single reactor. Because it is a recently developed system, this study aimed to present a simplified methodology for sizing the main components of a wastewater treatment plant (WWTP) with LGA in full-scale. To meet the future demand of Mangueira WWTP (average flow of 96.35 L/s until 2047), two sequential batch reactors (SBR) of constant volume with 1514 m³, 20 meters diameter in an area of approximately 0.65 hectares are required. The cycle of the reactors would have a total duration of 4 hours (simultaneous feed and discharge phase set at 45 minutes, aerobic reaction time of 2 hours and 45 minutes and a rest phase of 30 minutes) and a food/microorganism ratio of 0.4 kgCOD/kg.TSS.day. It was verified that it is possible to implement a WWTP with AGS from a technical and environmental point of view, especially when good treatment efficiency is sought, in a place with little available area. It was found that to supply the future treatment needs of the Mangueira WWTP with the application of AGS, an area 52% smaller than the current treatment with UASB and polishing ponds is needed. | pt_BR |
| dc.subject.cnpq | Áreas::Engenharias::Engenharia Civil | pt_BR |
| dc.degree.departament | ::(CTG-DECV) - Departamento de Engenharia Civil | pt_BR |
| dc.degree.graduation | ::CTG-Curso de Engenharia Civil | pt_BR |
| dc.degree.grantor | Universidade Federal de Pernambuco | pt_BR |
| dc.degree.local | Recife | pt_BR |
| dc.contributor.advisor-coLattes | http://lattes.cnpq.br/1982489326524742 | pt_BR |
| Appears in Collections: | (TCC) - Engenharia Civil e Ambiental | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| TCC Wallaces Paulo da Silva.pdf | 1.9 MB | Adobe PDF | ![]() View/Open |
This item is protected by original copyright |