Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufpe.br/handle/123456789/46624
Comparte esta pagina
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | LEITE, Wanderli Rogério Moreira | - |
dc.contributor.author | MESQUITA JUNIOR, Geovane Gregório de | - |
dc.date.accessioned | 2022-09-21T21:20:18Z | - |
dc.date.available | 2022-09-21T21:20:18Z | - |
dc.date.issued | 2017-09-21 | - |
dc.date.submitted | 2022-09-21 | - |
dc.identifier.citation | MESQUITA JUNIOR, Geovane Gregório de. Estudo da perda de carga em filtros de areia usados no pós-tratamento de esgotos domésticos. 2017. 49 f. TCC (Graduação) - Curso de Engenharia Civil, Centro de Tecnologia e Geociências, Universidade Federal de Pernambuco, Recife, 2017. | pt_BR |
dc.identifier.uri | https://repositorio.ufpe.br/handle/123456789/46624 | - |
dc.description.abstract | O presente trabalho teve como objetivo avaliar a perda de carga, turbidez, tempo da carreira de filtração e operação de retrolavagem ocorridos no pós-tratamento de esgoto domésticos realizado por filtros de areia descendentes, operando em paralelo com taxas de filtração de 60m3/m2.dia e 90m3/m2.dia. A pesquisa foi realizada na estação piloto do Laboratório de Saneamento Ambiental (LSA) da UFPE, localizada na ETE Mangueira em Recife-PE. O filtro que operou com taxa de filtração de 60 m3/m2.dia obteve tempo de duração máxima da carreira de filtração de 45 horas. Enquanto que para o filtro com taxa de filtração de 90 m3/m2.dia, a carreira de filtração alcançou 39h. Em todas as carreiras de filtração a interrupção se deu por atingir toda a carga hidráulica disponível. Os resultados de monitoramento dos filtros sugerem que a aplicação de uma taxa de filtração mais elevada resulta em menor duração da carreira de filtração, menor eficiência de remoção e maior volume de efluente tratado. Os dados de turbidez dos filtros mostram que o sistema foi capaz de atender os níveis de lançamento em corpos d’água, atendendo ainda padrões de reúso urbano não potável, em relação à turbidez. O volume necessário de água limpa para a retrolavagem dos filtros de areia correspondeu aproximadamente a 12 % do volume total do efluente tratado pelo filtro, porcentagem considerada elevada. | pt_BR |
dc.format.extent | 49p. | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | openAccess | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | * |
dc.subject | Engenharia Civil | pt_BR |
dc.subject | Comportamento da turbidez | pt_BR |
dc.subject | Filtro de granular | pt_BR |
dc.subject | Esgoto | pt_BR |
dc.title | Estudo da perda de carga em filtros de areia usados no pós-tratamento de esgotos domésticos. | pt_BR |
dc.type | bachelorThesis | pt_BR |
dc.degree.level | Graduacao | pt_BR |
dc.contributor.advisorLattes | http://lattes.cnpq.br/956377597087173 | pt_BR |
dc.description.abstractx | The aim of the present work was to evaluate the load loss, turbidity, filtration time and backwashing during the post-treatment of domestic sewage by descending sand filters, operating in parallel with filtration rates of 60m3/m2. day and 90m3/m2.day. The research was carried out at the pilot station of the Environmental Sanitation Laboratory (LSA) of UFPE, located at ETE Mangueira in Recife-PE. The filter operating at a filtration rate of 60 m3/m2.day yielded a maximum run time of 45 hours, while the time for 90 m3/m2.day reached 39h. In all filtration trials the interruption step followed the avaliable hydraulic load. The monitoring of the filters suggests that the application of a higher filtration rate results in a shorter filtering step, lower removal efficiency and higher volume of treated effluent. The turbidity data of the filters showed that the system is able to meet the levels of discharge, also meeting non-potable urban reuse standards. The required volume of clean water for a the sand filters backwashing accounted 12% of the total effluent treated by the filter. | pt_BR |
dc.subject.cnpq | Áreas::Engenharias::Engenharia Civil | pt_BR |
dc.degree.departament | ::(CTG-DECV) - Departamento de Engenharia Civil | pt_BR |
dc.degree.graduation | ::CTG-Curso de Engenharia Civil | pt_BR |
dc.degree.grantor | Universidade Federal de Pernambuco | pt_BR |
dc.degree.local | Recife | pt_BR |
Aparece en las colecciones: | (TCC) - Engenharia Civil e Ambiental |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
GEOVANE GREGÓRIO DE MESQUITA JUNIOR-ESTUDO DA PERDA DE CARGA EM FILTROS DE AREIA USADOS NO PÓS-TRATAMENTO DE ESGOTOS DOMÉSTICOS .pdf | 2,06 MB | Adobe PDF | ![]() Visualizar/Abrir |
Este ítem está protegido por copyright original |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons