Skip navigation
Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufpe.br/handle/123456789/45936

Comparte esta pagina

Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMOREIRA, Maurício Renato Pina-
dc.contributor.authorCASTRO, Yasmin Menezes-
dc.date.accessioned2022-08-24T19:49:29Z-
dc.date.available2022-08-24T19:49:29Z-
dc.date.issued2014-08-28-
dc.date.submitted2022-08-24-
dc.identifier.citationCASTRO, Yasmin Menezes. Dimensionamento do pavimento da Avenida Conde da Boa vista para o BRT. 2014. 66 f. TCC (Graduação) - Curso de Engenharia Civil, Centro de Tecnologia e Geociências, Universidade Federal de Pernambuco, Recife, 2014.pt_BR
dc.identifier.urihttps://repositorio.ufpe.br/handle/123456789/45936-
dc.description.abstractO objetivo do presente trabalho é prever as cargas atuantes na Avenida Conde da Boa Vista, que terá o tráfego composto exclusivamente por veículos BRT. Faz-se necessário um bom estudo do projeto para que a estrutura não seja dimensionada erroneamente. Desse modo, foram seguidas as normas disponibilizadas pelo DNIT. Através do método da PCA foi calculada a espessura da placa de concreto para três sub-bases diferentes a fim de compará-las e chegar na melhor solução (em função de qualidade e economia). Também foi feita uma comparação do dimensionamento do pavimento calculado com o dimensionamento atual para verificar se atende às novas solicitações de carga, além de um breve comentário acerca das condições atuais do pavimento.pt_BR
dc.format.extent66p.pt_BR
dc.language.isoporpt_BR
dc.rightsopenAccesspt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/*
dc.subjectEngenharia Civilpt_BR
dc.subjectDimensionamentopt_BR
dc.subjectPavimento de Concretopt_BR
dc.subjectAvenida Conde da Boa Vistapt_BR
dc.subjectBRTpt_BR
dc.titleDimensionamento do pavimento da Avenida Conde da Boa vista para o BRTpt_BR
dc.typebachelorThesispt_BR
dc.degree.levelGraduacaopt_BR
dc.contributor.advisorLatteshttp://lattes.cnpq.br/1554286042363904pt_BR
dc.description.abstractxThe purpose of this study is to predict the loads acting on Conde da Boa Vista Avenue, which will have its traffic composed exclusively of BRT vehicles. It is necessary a good study of the project so that the structure is not scaled wrongly. Thus, the norms provided by DNIT were followed. Through the PCA method the thickness of the concrete slab for three different sub-bases was calculated in order to compare them and get the best solution (in terms of quality and economy). Also a comparison of the design of the pavement with the current calculated to verify that meets the new load requests sizing, plus a brief comment about the current condition of the pavement.pt_BR
dc.degree.departament(CTG-DECV) - Departamento de Engenharia Civil pt_BR
dc.degree.graduationCTG-Curso de Engenharia Civilpt_BR
dc.degree.grantorUniversidade Federal de Pernambucopt_BR
dc.degree.localRecifept_BR
Aparece en las colecciones: (TCC) - Engenharia Civil e Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
YASMIN MENEZES CASTRO - DIMENSIONAMENTO DO PAVIMENTO DA AVENIDA CONDE DA BOA VISTA PARA O BRT (2).pdf7,88 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons